Brand Name :YOKG
Model Number :LR2-D13, LR2-D25, LR2-D33, LR2-D43
Certification :CE
Place of Origin :China
MOQ :100PCS
Price :Negotiable
Payment Terms :L/C, D/P, T/T
Supply Ability :100000pcs per Month
Delivery Time :15days or Depends on ordering QTYS
Packaging Details :Standard export packing or According to customer's demand
Usage :Protective
Theory :Thermal Relay
Frequency :50Hz/60Hz
Rated Current :0.1A-93A
Rated working current :25,36,93A separately
OEM :Available
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

LR2-D13 Series 36A Electromechanical Magnetic Thermal Overload Relay

Application:

LR2-D series thermal relay can be used in the circuit of 50Hz or 60Hz, rated insulation voltage 660V, rated current 0.1-93A for protecting the phase break when the electric motor is overload.

The relay has different mechanism and temperature compensation & can be pluged in LC1-D series AC contactor. It is the most advanced thermal relay in the nineties in the world.

A. Fundamental parameter of the main circuit
(a). Rated insulation voltage 660V.
(b). Rated working current 25,36,93A separately.
(c). The regulator seal of rated setting current and setting.
(d). Current of the thermal component(see list 1)

B. Auxiliary Circuit
(a). There is one pair of NO/ and N/C contact with electric insulation.
(b). Rated insulation voltage 500V.
(c). Rated frequency 50-60Hz.
(d). Use group, rated working voltage ,appoint thermal current and rated current.

Motion Characteristic: Three-phase Balance Motion Time

No Times of the setting current Motion time Start condition Ambient temperature
1 1.05 >2h Cold state 20±5oC
2 1.2 <2h Heat state(Following the No.1 test)
3 1.5 <4min
4 7.2 10A 2s< Tp≤10s ≤63A Cold state
10 4s< Tp≤10s >63A

Phase-losing Motion Characteristic

No Times of the setting current Motion time Start condition Ambienttemperature
Any two phases Another phase
1 1.0 0.9 >2h Cold state 20±5oC
2 1.15 0 <2h Heat state(Following the No.1 test)

Type Number Setting range (A) For contactor
LR2-D13 1301 0.1~0.16 CJX2-09~32
1302 0.16~0.25 CJX2-09~32
1303 0.25~0.4 CJX2-09~32
1304 0.4~0.63 CJX2-09~32
1305 0.63~1 CJX2-09~32
1306 1~1.6 CJX2-09~32
1307 1.6~2.5 CJX2-09~32
1308 2.5~4 CJX2-09~32
1310 4~6 CJX2-09~32
1312 5.5~8 CJX2-09~32
1314 7~10 CJX2-09~32
1316 9~13 CJX2-09~32
1321 12~18 CJX2-09~32
1322 17~25 CJX2-32
LR2-D25 2353 23~32 CJX2-09~32
2355 30~40 CJX2-09~32
LR2-D33 3322 17~25 CJX2-09~32
3353 23~32 CJX2-09~32
3355 30~40 CJX2-09~32
3357 37~50 CJX2-09~32
3359 48~65 CJX2-09~32
3361 55~70 CJX2-09~32
3363 63~80 CJX2-09~32
3365 80~93 CJX2-95
LR2-D43 4365 80~104 CJX2-95
4367 95~120 CJX2-95~115
4369 110~140 CJX2-115

Type Rated working current of thermal relay Thermal component
Rated current(A)

Rated or scale of

rated current (A)

LR2-D13 25 LR2-D1301 0.16 0.10-0.16
LR2-D1302 0.25 0.16-0.25
LR2-D1303 0.4 0.25-0.40
LR2-D1304 0.63 0.40-0.63
LR2-D1305 1 0.63-1.0
LR2-D1306 1.6 1.0-1.6
LR2-D13x6 2 1.25-2.0
LR2-D1307 2.5 1.6-2.5
LR2-D1308 4 2.5-4.0
LR2-D1310 6 4.0-6.0
LR2-D1312 8 5.5-8.0
LR2-D1314 10 7.0-10.0
LR2-D1316 13 9.0-13.0
LR2-D1321 18 12.0-18.0
LR2-D1322 25 17.0-25.0
LR2-D23 36 LR2-D2353 32 23.0-32.0
LR2-D2355 36 28.0-36.0
LR2-D33 93 LR2-D3353 32 23.0-32.0
LR2-D3355 40 30.0-40.0
LR2-D3357 50 37.0-50.0
LR2-D3359 65 48.0-65.0
LR2-D3361 70 55.0-70.0
LR2-D3363 90 63.0-80.0
LR2-D3365 93 80.0-93.0

36A Electromechanical Protection Relay Thermal Overload Magnetic LR2-D13 Series

36A Electromechanical Protection Relay Thermal Overload Magnetic LR2-D13 Series

36A Electromechanical Protection Relay Thermal Overload Magnetic LR2-D13 Series

36A Electromechanical Protection Relay Thermal Overload Magnetic LR2-D13 Series

Certificates:
36A Electromechanical Protection Relay Thermal Overload Magnetic LR2-D13 Series


Packing and Delivery:
36A Electromechanical Protection Relay Thermal Overload Magnetic LR2-D13 Series

36A Electromechanical Protection Relay Thermal Overload Magnetic LR2-D13 Series

36A Electromechanical Protection Relay Thermal Overload Magnetic LR2-D13 Series

Why Choose Us:
---------------------------------------------
a. Reply your inquiry in 24 working hours.
b. Technical and professional guidance.

c. We do the quality products according to the IEC standards.
d. Nearly 20 years export experience in the overseas market
We maintain excellent products and strive for 100% customer satisfaction. A good feedback is very important, we welcome for your kind suggestion or feedback on goods and our service.


FAQ:
1. Could I have prices of your products?
Well welcome. Please feel free to send us any inquiry. You will get our reply in 24 hours.

2. Can we print our logo/website/company name on products?
Yes, OEM and ODM are available.

3. What's the lead time for regular order?
7-15 days for order quantity less than 2000pcs. For more quantity, we can negotiate about it.

4. Do you inspect the finished products?
Our products 100% self-inspection and testing before packing.

5. How about payment terms?

Standard order could pay by T/T,L/C, Small order could support Western Union